Tag: Resichem 555 Resinox

Corroded odor control enclosure before repair

Odor Control Enclosure Repair for Water & Wastewater Facilities

Corrosion Protection for Odor Control Enclosures Exposed to H2S and Treatment Chemicals Odor control systems play a critical role in water and wastewater treatment facilities, but the enclosures that house…
Read more

metal roof repair

Metal Roof Repair on WWTP Building

The Problem Metal roof repair: This WWTP was seeing extensive corrosion with their infrastructure. The corrosion was so advanced that it was causing the roof to leak. The facility was…
Read more

Bridge Protection

Bridge Protection

The Problem Weathered Steel also known as ASTM A-588, ASTM A-242, or Cor-Ten works well in many environments, and gives structures a rustic look. However, in areas with lots of…
Read more

Lookout Station Corrosion Protection

The Problem   The Army Corps of Engineers Look Out Station was grappling with the detrimental impact of corrosion, which was progressively weakening its structural integrity and compromising its overall…
Read more

Resichem 555 Resinox with Jeff Brown from Buckeye Pipeline

Thank you everyone for joining in on another USI Group #TechTalk. In today’s episode, we chat with Jeff Brown from Buckeye Pipeline, who shares his thoughts on our Resichem 555…
Read more

Wastewater Plant 54” Pipe Repair

The Problem A city wastewater plant in Michigan needed to protect their pipe before the wall thickness became too thin and they were forced to replace. This would have been…
Read more

Generator Building

The Problem   A wastewater company wanted to invest in stopping corrosion by protecting their generator building from the outside elements. Instead of allowing corrosion to continue they thought it…
Read more

Diesel Tank Refurbishment

Diesel Tank Refurbishment for Long-Term Protection

The Problem Diesel Tank Refurbishment: The current coating on the steel tank was beginning to fade due to exposure to the elements, and the customer wanted to enhance and improve…
Read more

Tank Chime Repair

The Problem A wastewater company was looking for a cost-effective and durable repair solution for their tank chimes. There was a 1½ in. gap that needed to be repaired and…
Read more

Corrosion Protection for a Steel Bridge

Corrosion Protection for a Steel Bridge at a Large Steel Mill

The Problem A bridge at a large steel mill was experiencing severe corrosion they needed corrosion protection for their steel bridge. The traditional method of grit blasting to prepare the…
Read more

Request a Quote

We will respond within one business day

Before you go..